Buffer Cleaner
Oman Chemical is leading one Largest Supplier, Manufacture a
Product Code: RXSOL-42-1524-035
| Solubility (10 % Aquous Soln) | V. S. Hazy to clear solution. |
| pH Value of 5% Solution | 3.5 to 4.5 |
| Specific Gravity @ 25° C | 1.310 – 1.370 |
| Density, lbs/gal @ 25° C | 10.9 - 11.3 |
| Description | Oxygen Scavenger for Boiler |
| Standard Packing | 30 Kg / 50 Kg. / 250 kg HM HDPE Barrel |
The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.
Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.
The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.
The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation
It is used to arrest oxygen in sea water
It removes Entrapped Oxygen and thus reduces Corrosion
In Oil Drilling Chemicals

Product Code: RXSOL-60-6001-210
| CharactersItics | Properties | |
| Appearance Thermal Firmness | Clear yellow liquid 250° C | By keeping heat transfer surfaces free of scale, Ensures that the evaporator works at maximum efficiency. |
| Density | In g/cm3 at 15°C: 1.1 |
Permits more efficient evaporation. |
| pH (1 Vol%) | 9 |
Reduces downtime and maintenance costs. |
| Compatibility | Concentrated, safe liquid, easy and economical dosing. | |
| Metal | No known effect |
For use in both high pressure and vacuum evaporators |
| Rubber | No known effect | The antifoaming properties ensure that distillate quality is high |
| Packaging |
20 / 25 ltr |
Improves the quality of distilled water |
RXSOL-51-6001-025 is a concentrated solution of a POLYELECTROLYTE polymer and Antifoaming Agents for use in SEA WATER evaporator as a controller of scale and foam in side the evaporators. It can be used as a scale inhibitor in the feed water to EVAPORATORS producing fresh water .
A liquid polymer-based evaporator treatment specially designed to control and prevent scale formation in evaporators

Product Code: RXSOL-14-5005-554
Basic Boiler System Schematic
Below is a summary of problems associated with the common impurities in water and solutions to each problem.
List Of Problems Caused By Impurities In Water
|
Impurity (Chemical Formula) |
Problems |
Common Chemical Treatment Methods |
|
Alkalinity (HCO3-, CO32- and CaCO3) |
Carryover of feedwater into steam, produce CO2 in steam leading to formation of carbonic acid (acid attack) |
Neutralizing amines, filming amines, combination of both, and lime-soda. |
|
Hardness (calcium and magnesium salts, CaCO3) |
Primary source of scale in heat exchange equipment |
Lime softening, phosphate, chelates and polymers |
|
Iron (Fe3+ and Fe2+) |
Causes boiler and water line deposits |
Phosphate, chelates and polymers |
|
Oxygen (O2) |
Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack) |
Oxygen scavengers, filming amines and deaeration |
|
pH |
Corrosion occurs when pH drops below 8.5 |
pH can be lowered by addition of acids and increased by addition of alkalies |
|
Hydrogen Sulfide (H2S) |
Corrosion |
Chlorination |
|
Silica (SiO2) |
Scale in boilers and cooling water systems |
Lime softening |

Product Code: RXSOL-42-1308-025

Product Code: RXSOL-42-5029-200
| Appearance | Clear Liquid |
| Odor | Amine like |
| pH | 10-11 |
#OxygenScavengerforBoiler
#OxygenScavengermanufacturer
#OxygenScavengersupplier
#AminebasedOxygenScavenger

Product Code: RXSOL-42-5001-025
Boiler Water Treatment products
CHARACTERISTIC :
RXSOL-42-5001-025 Boiler Water treatment specialized is a well - balanced blend for boiler water treatment products, Resulting Multi Functional Boiler Treatment including scale and corrosion control by one shot operation. A one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressure up to 20 bars.
The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide.
Basic Boiler System Schematic
Below is a summary of problems associated with the common impurities in water and solutions to each problem.
List Of Problems Caused By Impurities In Water
|
Impurity (Chemical Formula) |
Problems |
Common Chemical Treatment Methods |
|
Alkalinity (HCO3-, CO32- and CaCO3) |
Carryover of feedwater into steam, produce CO2 in steam leading to formation of carbonic acid (acid attack) |
Neutralizing amines, filming amines, combination of both, and lime-soda. |
|
Hardness (calcium and magnesium salts, CaCO3) |
Primary source of scale in heat exchange equipment |
Lime softening, phosphate, chelates and polymers |
|
Iron (Fe3+ and Fe2+) |
Causes boiler and water line deposits |
Phosphate, chelates and polymers |
|
Oxygen (O2) |
Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack) |
Oxygen scavengers, filming amines and deaeration |
|
pH |
Corrosion occurs when pH drops below 8.5 |
pH can be lowered by addition of acids and increased by addition of alkalies |
|
Hydrogen Sulfide (H2S) |
Corrosion |
Chlorination |
|
Silica (SiO2) |
Scale in boilers and cooling water systems |
Lime softening |

Product Code: RXSOL-42-6005-250
| Appearance | Clear, Yellowish Amber Liquid |
| Flash point | Non-flammable |
| Solubility in water | Soluble in all proportions |
| Freezing Point | -15 Degree |
SAFETY INFORMATION:
Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information).
SAFETY INFORMATION:
Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information).
Antiscalant 9209 RX is compatible with carbon steel and other commonly used materials of construction. Observe all safety precautions shown in the material safety data sheet, available on request.

Product Code: RXSOL-42-5029-180

Product Code: RXSOL-42-1541-030
Physical properties
| Molecular formula: | H2NNH2 |
| CAS No.: | 000302012 |
| Molecular weight: | 32.05 |
| Description: | colorless, oily liquid, fuming in air. |
| Odor: | penetrating odor resembling that of ammonia |
| Density: | 1.0036 (25/4°C) |
| Boiling point: | 113.5°C (at 760 mm Hg) |
| Freezing point: | 1.4 - 1.5°C |
| Explosive limits: | 4.7 - 100% by volume in air |
| Flash point: | 38 - 52°C (open cup) |
| Saturation concentration: | 18900 ppm |
| Conversion factors: | 1 ppm = 1.31 mg/m3 |
| (at 760 mm and 25°C) | 1 mg/m3 = 0.76 ppm |
| Solubility: | soluble in water, ethanol, and isobutanol; insoluble in chloroform and ether |
| Vapor density: | 1.04 (air = 1) |
| Vapor pressure: |
14.4 mm Hg at 25°C |
Hydrazine is used as an oxygen scavenger for high pressure boilers in power plants and other industries to reduce corrosion of metal pipes and fittings. Hydrazine Test Method, in which several solutions have been formulated as a Hydrazine Reagent. The method is both sensitive and easy to perform. It is used mostly for the determination of small amounts of hydrazine in boiler feedwater.

Product Code: RXSOL-42-1977-026