Sodium Molybdate 35%

Size:

Color:

Product Short Description: Corrosion inhibitor to protect metal surface in water syste.
Product Technical Specification:

Sodium Molybdate Specification :

Specification                Limit
Molecular Formula NA2MOO4.2H2O
CAS No 10102-40-6
Molecular Weight 241.95
Na2MoO4 x H2O  40.7 - 41.6% wt.
Na2MoO4 34.7 - 35.4% wt.

Molybdenum

16.2 - 16.5% wt.
pH 8.5 - 10.0
Specific gravity 1.377 - 1.386 (24C)
Mercury, as Hg <= 0.005%
Chloride (Cl)  ≤ 0.005%
Phosphate(PO4)  ≤ 0.05%
Sulfate ≤ 0.15%
Ammonium (NH4) ≤ 0.001%
Heavy Metal (Pb) ≤ 0.001%
Solubility in Water Soluble
 
Remarks:
Images: Alt

Sodium Molybdate

Size:

Color:

Product Short Description: Sodium molybdate Na2MoO4 is useful as a source of molybdenum
Product Technical Specification:

Sodium Molybdate Specification :

Molecular Formula NA2MOO4.2H2O
CAS No 10102-40-6
Molecular Weight 241.95
Appearance  White crystalline powder

Assay

98 - 99.5% Min
Chloride (Cl)  ≤ 0.005%
Phosphate(PO4)  ≤ 0.05%
Sulfate ≤ 0.15%
Ammonium (NH4) ≤ 0.001%
Heavy Metal (Pb) ≤ 0.001%
 
Remarks:

leading Indian Manufacturers of Sodium Molybdate, Ammonium Molybdate and Molybdenum Trioxide.

Sodium Molybdate is Roasted Molybdenum oxide/Canada/USA/ Belgium.

Our other valuable molybednum product list is as follows :::

  1. Sodium Molybdate
  2. Ammonium Para / Hepta Molybdate
  3. Ammonium Di Molybdate
  4. Ammonium Tetra Molybdate
  5. Molybdenum Trioxide
  6. Ferrous Fumarate (IP  / BP / USP / EP) 
  7. Fumaric Acid (IP / USP)
  8. Ferrous Sulphate Heptahydrate (IP / BP)
  9. Dried Ferrous Sulphate (IP / BP / USP) 
  10. Zinc Sulphate Heptahydrate (IP / BP) 
  11. Zinc Sulphate Monohydrate
  12. Dried Ferrous Sulphate Tech / Feed Grade / Pure Grade
  13. Ferrous Sulphate Heptahydrate Tech Grade  / Agro 
  14. Ammonium Sulphate Tech / Agri. Grade
  15. Magnesium Sulphate Heptahydrate/Tech/Agro
  16. Manganese Sulphate Tech / LR Grade
  17. Copper Sulphate Pentahydrate Tech / LR Grade
  18. Dried Magnesium Sulphate
  19. Zinc Sulphate Heptahydrate Tech 21%
  20. Zinc Sulphate Monohydrate 33%, 28%
  21. Boron 11%, 15%, 21%, Cobalt Sulphate
  22. Sodium Acetate, Sodium Sulphate
  23. Dicalcium Phosphate
  24. Tricalcium Phosphate
  25. Nickel Sulphate
  26. Chromium Chloride, Sodium thiosulfate
  27. Ammonium Molybdate
  28. Sulphur

All the above products are available in different grades like AR/LR/ACS/TECHNICAL with different purity levels and concentrations.

Images: Alt

Corrosion Inhibitor Nitrite Borax based

Size:

Color:

Product Short Description: High performance nitrite-borate formulation with an additional organic inhibitor for closed circuit inhibitor to protect steel, copper and other non-ferrous metals
Product Technical Specification:

Appearance

Colourless 

Odour

Odourless 

pH

11-12 approx

Boiling Point / Boiling Range

Not determined

Melting Point/Melting Range

N/A

Flash Point N/A
Flammability Non flammable
Autoflammability N/A
Explosive Properties N/A
Oxidising Properties N/A
Vapour Pressure Not determined
Relative Density 1.18 approx
Solubility in water  Miscible
Solubility in other solvents  Not determined
Partition coefficient and N-octanol/water  ----------
Other Data None
 
Remarks:
TREATMENT                         Feature
Sodium Nitrate                       Iron and Steel corrosion inhibitor. 800-2500 ppm recommended.
Molybdate                              Slows the growth of bacteria.
Tolyltriazole                            Copper corrosion Inhibitor.
Synthetic polymer                  Prevents hard scale built up.
Borax buffer                           Corrects the water pH (Maintain pH level between 8.5 to 9.2).
Silicates                               A common corrosion inhibitor used by automotive antifreeze suppliers is silicates. Silicates have the disadvantage of building up an insulating layer on components and are not recommended for industrial engines. Concentration should not exceed 25 ppm.
Images: Alt

Pennstopsol 85 (Corrosion Inhibitor)

Size:

Color:

Product Short Description: short-stopper in styrenique rubber polymerization - oxygen scavenger (anticorrosion boiler water trea tment),
Product Technical Specification:
Remarks:
Images: Alt

Acid Corrosion Inhibitor RXSOL 213

Size:

Color:

Product Short Description: The addition of Acid corrosion Inhibitor RXSOL 213, inhibitors to hydrochloric acid solution provides maximum protection for equipment during,The removal of lime deposits or water scale from power plant boilers and piping systems and from evaporating equi
Product Technical Specification:

ACID inhibitor for HCl, Hydrochloric Acid. 

During Acidization corrosion prevention must required to protect metal surface from ACID effect. Inhibited hydrochloric acid  (HCl), HF doesn't damage metal surface. 
Remarks:

Acids and corrosive materials are used to enhance production and to stimulate reservoirs therefore special care is required to ensure that casing, tubing strings and downhole equipment are not damaged. Blend of ACID with Acid corrosion Inhibitor RXSOL 213 protect your downhole equipment and metal tubulars.

Images: Alt

Corrosion Inhibitor Carbon Dioxide and H2S

Size:

Color:

Product Short Description: To Prevent H2S Corrosion in distillation Columns overhead system. H2S Scavengers and Speaciality Chemicals to Reduce Hydrogen Sulfide Exposure
Product Technical Specification:

Hydrogen Sulfide Scavenger Manufacturer, supplier, Exporter. Product Code :  RXSOL-11-5014-210 is very effective  corrosive and Acidic GAS Remover. H2S Scavengers and Speaciality Chemicals to Reduce Hydrogen Sulfide Exposure from atmosphere.

Remarks:

H2S Scavengers and Speaciality Chemicals to Reduce Hydrogen Sulfide Exposure

Harmful and Colorless toxic gas, Toxic Odor like rotten egg in to the working environment is due to presence of good amount of Hydrogen Sulfide in the system.  

Hydrogen Sulfide is corrosive and Acidic GAS towards metal equipment practically observed that within 5 years can cause millions of dollars in damage to infrastructure.

RX Marine International offers a compleate line of water soluble and oil soluble hydrogen sulfide scavengers that can be applied via continous injection or through batch treatments.

HS Code : 3811900

Images: Alt

Corrosion Inhibitor

Size:

Color:

Product Short Description: Corrosion inhibitor especially designed to inhibit the attack of hydrochloric acid and steel during industrial cleaning operations. It also inhibits acid attack on copper and brass. It does not contain arsenic, chlorinated hydrocarbons, or lead compounds.
Product Technical Specification:

Corrosion inhibitor that is used on metal equipment and surfaces that are acid cleaned to prevent the formation of rust.

Remarks:

Safety and Handling : 

Before handling the chemical products used in this process, the first aid and handling recommendations on the Material Safety Data Sheet for should be read, understood and followed. The industrial cleaning bath is strongly acid and can burn skin and eyes. Refer to the Material Safety Data Sheet for hydrochloric acid for recommendations for protective action.

Images: Alt

Corrosion Inhibitor for Gas Compressor

Size:

Color:

Product Short Description: Corrosion Inhibitor for Gas Compressor
Product Technical Specification:

 

Test type ASTM method Corrosion Inhibitor
ISO VG   100
     
Water content, ppm D6304 20
Acid number TAN, mgKOH/g D974 1.32
Flash and fire point D92  
Flash point, °C   243
Ignition temperature, °С   268
Kinematic viscosity, cSt D445  
40°C   107.2
100°C   11.7
Viscosity index D2270 116
Pour point, °C D97 -37
Demulsibility D1401  
Oil-Water-Emulsion (time in minutes)   39-40-1 (10)
Volatility by NOACK D972  
Losses in % mass   2.9 
Copper Tape Corrosion D130  
100°C, 3 hours   1A
Corrosion D665  
A - in distilled water   Pass
B - in sea water   Pass

These products are also available in other viscosity grades and packaging. Additional test results are available upon request. 

 

 

Remarks:

Corrosion Inhibitor for Gas Compressor are efficient corrosion inhibitors developped to protect oil and gas production installations against internal corrosion. This includes protection of water systems specific to oil fields (produced water disposal systems and production, treatment and injection waters facilities). Corrosion Inhibitor for Gas Compressor offers an optimum corrosion inhibition whatever the fluid characteristics and field conditions: CO2 and/or H2S p

Images: Alt

Corrosion Inhibitor

Size:

Color:

Product Short Description: Corrosion inhibitor especially designed to inhibit the attack of hydrochloric acid on iron and steel during industrial cleaning operations. It also inhibits acid attack on copper and brass. It does not contain arsenic, chlorinated hydrocarbons, or lead compounds.
Product Technical Specification:

Safety and Handling : 

Before handling the chemical products used in this process, the first aid and handling recommendations on the Material Safety Data Sheet for should be read, understood and followed. The industrial cleaning bath is strongly acid and can burn skin and eyes. Refer to the Material Safety Data Sheet for hydrochloric acid for recommendations for protective action.

Remarks:
Images: Alt

RXSOL 4000

Size:

Color:

Product Short Description: Corrosion inhibitor is a catalyzed liquid Oxygen Scavenger, This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental conditions such as high heat and humidity, seawater or other
Product Technical Specification:
 
Form                                         Liquid
Colour Colourless to slightly Yellow
Odour Sharp
Flash Point  > 100 degree C
Density 1.05-1.11 g/cm3 (25C)
pH 3 - 7
 

 

Non-Flammable

Safe Plant Handling
Low Odor
Provides corrosion protection in the liquid and the vapor phase
When used in hydrostatic testing the product provides protection in liquids below, above and at the liquid levels. Protection of recessed and hard to reach areas. Complicated valves and the interior surfaces of piping and equipment, which are often difficult or impossible to reach, are protected with true Vapor Corrosion Inhibitor action. Can be applied for hydrotest solution, metalworking fluids, coatings, adhesives and water treatment formulations.


 

Remarks:

Risk of serious damage to eyes. In case of contact with eyes, rinse immediately with plenty of water & seek medical advice.  Wear suitable gloves and eye / face protection

Images: Alt
stock-clearance.png