Buffer Cleaner
Oman Chemical is leading one Largest Supplier, Manufacture a
Antiscalant RO is a liquid antiscalant designed to inhibit scale in cellulose acetate and polyamide membrane separation systems. The formulation contains a 35% by weight solution of poly acid that has a tight molecular weight range of 2000.
This product is designed for use in waters that do not have a high potential for colloidal and silt fouling of RO membrane surfaces (i.e. groundwater applications).
Antiscalant RO can be injected neat or diluted and a site‐specific dosage can be determined.
Application:
Antiscalant RO performance is achieved when the chemical is injected downstream of multimedia filters and upstream of cartridge filters. For maximum effectiveness, Antiscalant RO should be added prior to the static mixer or cartridge filter housing. For potable the maximum dosage is 10 mg/L. Maximum dilution is 10% with RO permeate or DI water
It reduces the risk of scaling and eliminates the use of hazardous acids, resulting in efficient plant operation with highest possible conversion rate.
It is a very effective antiscalant. It is also compatible with RO CHEMICALS series of coagulant and flocculants (polyelectrolytes). Our RO Antiscalant (HIGH PH) is effective in minimizing scaling in presence of foulants like Calcium Carbonate, Sulfate salts of Calcium, Barium, Strontium and Magnesium, Calcium Fluoride, Iron and Silica.
Pl. refer our Technical Bulletine and MSDS of Product.
This advanced, high strength formulation available in powder / liquid form
• pH adjusted to 3.0+ 0.5
• Highly effective at ambient temperatures
• Contains no surfactants and is quickly rinsed away
• Contains organic acids, detergent builders and chelating agents
Safety Goggles, And Hand Gloves is compoulsery before using this product. And for more details pl. ask MSDS.
Membrane Cleaner RXSOL- 3304 MC3 is a low pH formulation that has been designed specifically to remove metal hydroxides, calcium carbonate and other similar scales from polyamide, polysulfone and thin film, composite membrane surfaces.
TRANSPORT INFORMATION:-
Appearance : Liquid
Colour : Colorless to pale yellow
Proper Shipping Name : Cleaning Chemicals
Odour : Mild
UN Number : UN 1789
Packaging Group : II
|
|
Properties |
|
Molecular formula |
HCl in water (H2O) |
Molar mass |
36.46 g/mol (HCl) |
Appearance |
Clear colorless to light-yellow liquid |
Melting point |
−26°C (247 K) 38% solution |
Boiling point |
110 °C (383 K), 20.2% solution; |
Solubility in water |
Miscible |
Acidity (pKa) |
−8.0 |
Viscosity |
1.9 mPa s at 25° C, |
Flash point |
Non-flammable |
Safety
Hydrochloric acid in high concentrations forms acidic mists. Both the mist and the solution have a corrosive effect on human tissue, with the potential to damage respiratory organs, eyes, skin, and intestines. Upon mixing Muriatic acid with common oxidizing chemicals, such as bleach (NaClO) or permanganate (KMnO4), the toxic gas chlorine is produced. To minimize the risks while working with hydrochloric acid, appropriate precautions should be taken, including wearing rubber or PVC gloves, protective eye goggles, and chemical-resistant clothing.
PHYSICAL PROPERTIES:-
Because RXSOL-33-3302-020 is a highly concentrated product,
It is acceptable to use small doses of reagent.
Suspended substances such as dirt, bottom sediments, clay, metal oxides are dispersed, and their possible precipitation decelerates. The strong dispersing power of RXSOL-33-3302-020 allows the reagent to maintain its efficiency in waters with high total salt content, as well as in areas with a low liquid flow rate. Salts of calcium and magnesium, such as CaCO3, CaSO4, CaSO4 · H2O, MgSiO4, are dispersed, and the formation of their sediments is suppressed.
Appearance: cloudy, viscous liquid
Density (kg / m3): 1180
pH (approximately): 9.8
Solubility in water: soluble in any proportion
Flash point: not determined
These data can be considered as typical values, but by no means as specifications
Precautionary measures : Use protective gloves and goggles. If the reagent enters the skin, eyes, rinse with plenty of water, consult a doctor. If a reagent leakage is collected with sand or other absorbent material, rinse the contaminated surface with water. Before use, read the additional information in the Safety Instructions.