RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Corrosion Inhibitor

RXSOL 4000

Corrosion inhibitor is a catalyzed liquid Oxygen Scavenger, This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental conditions such as high heat and humidity, seawater or other
Part number
RXSOL-40-4035-025
Brand
RXSOL
RXSOL 4000

Overview

RXSOL 4000 is a multicomponent, multifunctional formulation which prevents corrosion, microbiological growth in single product treatment programme. Inhibitor, corrosion, multicomponent, multifunctional: For prevention of corrosion and microbiological growth in water flood systems during hydrostatic testing and other applications.

Technical specifications

Form                                         Liquid
Colour Colourless to slightly Yellow
Odour Sharp
Flash Point  > 100 degree C
Density 1.05-1.11 g/cm3 (25C)
pH 3 - 7
 

Non-Flammable

Safe Plant Handling
Low Odor
Provides corrosion protection in the liquid and the vapor phase
When used in hydrostatic testing the product provides protection in liquids below, above and at the liquid levels. Protection of recessed and hard to reach areas. Complicated valves and the interior surfaces of piping and equipment, which are often difficult or impossible to reach, are protected with true Vapor Corrosion Inhibitor action. Can be applied for hydrotest solution, metalworking fluids, coatings, adhesives and water treatment formulations.


 

Applications

PERFORMANCE:

CORROSION
: Effectively prevents corrosion due to Carbon Dioxide, inorganic salts, dissolved oxygen & Hydrogen sulphide contamination from sour fluid or bacterial action. The inhibitor acts as a cathodic polarizer

MICROBIOLOGICAL GROWTH: Effectively prevents the metabolic function necessary for reproduction of the bacteria cell. Successfully prevents anaerobic/aerobic and sulphate reducing bacteria.

The major factor which contributes to the corrosion in hydro-static test water is the dissolved oxygen and dissolved solids do not have much impact on the corrosion rate except the chloride content. The presumptions like not using the corrosion inhibitor if the water is not with high mineral content could be  disastrous as in fact any corrosion process, even a very mild one, will be accompanied by the set up of galvanic cells and formation of corrosion products deposits. Such environment makes the conditions ideal for the corrosion process to continue at accelerated rate once the process fluid will be run through the line.

Dosage and directions

RXSOL 4000 can be fed directly or through chemical doses pump. Doses may vary with the quality of water to be treated and the residence time of the water in the system.

Actual consumption is determined under operating conditions.

Characteristics and notes

Benefit  / Advantage :

RXSOL 4000 is a liquid multifunctional chemical designed to completely treat hydrostatic test fluid, saltwater packer fluid, saltwater drilling fluid, during Hydro-testing and oil field water injection programme.
 

RXSOL 4000 contains an effective filming corrosion inhibitor, oxygen scavenger and biocide, altogether in a single formulation convenient to dose with single chemical injection pump or skid.
 

RXSOL 4000 is economical to use as handling is limited to one chemical.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name : RXSOL 4000 Hydro Testing Corrosion Inhibitor
Part Number : RXSOL-40-4035-025

Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Branch : Kandla, JNPT,  Mumbai, Chennai, Vizag,  Kolkata, Fujairah UAE, Muscat Barka Oman

Phone +91 22 27815540 / 41 / 42
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
Website www.rxmarine.com
Name  of  Substance                          Cas Number EINECS No Wt.% Symbol
Ammonium Bisulphite 10192-30-0 203-469-7 10 -30 %  Xi
Ethanediol 107-21-1 203-473-3 10 - 30%  Xn
Quaternary Ammonium Chloride 68391-01-5 269-919-4 10 - 30%  C
Propan-2-ol 67-63-0 200-661-7 1 - 5 %  Xi
Proprietory Biocide Mixture --- --- --- ---

 

Signal Word                        None
Hazard Statements

Causes severe skin burns and eye damage.

Precautionary statements - prevention Keep only in original container. Wash skin thoroughly after handling. Wear protective gloves/ protective clothing/ eye protection/ face protection..
Precautionary statements - response IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER or doctor/ physician. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/ physician. Wash contaminated clothing before reuse. Absorb spillage to prevent material damage.
Storage: Store locked up. Store in corrosive resistant stainless steel container with a resistant inner liner.
Disposal: Dispose of contents/ container to an approved waste disposal plant.

  

Eye Contact Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention immediately.
Skin Contact Wash off immediately with plenty of water for at least 15 minutes. Use a mild soap if available. Wash clothing before reuse. Thoroughly clean shoes before reuse. Get medical attention immediately.
Inhalation:              If inhaled, If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician.
Ingestion: If swallowed, do not induce vomiting. Allow victim to rinse his mouth and then to drink 2-4 cupfuls of water. Never give anything by mouth to an unconscious person. Call a physician.
Notes to Physicians Treat symptomatically.
Suitable extinguishing media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Protective  Equipment                       Use personal protective equipment.
Hazardous combustionproducts Decomposition products may include the following materials:
Nitrous gases (NOx),Sulphur oxides,Ammonia (NH3) ,Amines.
Advice for firefighters Wear self-contained breathing apparatus. Wear full protective equipment.
Specific extinguishing methods Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. In the event of fire and/or explosion do not breathe fumes.
Personal precautions, protective equipment and emergency procedures

Ensure adequate ventilation. Keep people away from and upwind of spill/leak. Avoid inhalation, ingestion and contact with skin and eyes. Wear suitable personal protective equipment.Respiratory protective equipment.

Enviromental  Precaution  Do not allow contact with soil, surface or ground water.If the products get into drains, inform the relevant authorities immediately.
Methods and materials for
containment and cleaning up
Stop leak if safe to do so. Contain spillage, and then collect with noncombustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water. For large spills, dike spilled material or otherwise contain material to ensure runoff does not reach a waterway.
Advice on safe handling Do not ingest. Do not get in eyes, on skin, or on clothing. Do not breathe dust/ fume/ gas/ mist/ vapors/ spray. Use only with adequate ventilation. Wash hands thoroughly after handling.
Storage Do not store near acids. Keep out of reach of children. Store in suitable labeled containers. Storage temperature : 10 °C to 50 °C
Advice on general occupational hygiene Wash hands after use. Do not to eat, drink and smoke in work areas. Remove contaminated clothing and protective equipment before entering eating areas.
Engineering Control Effective exhaust ventilation system. Maintain air concentrations below occupational exposure standards.
Personal   Protection Eye protection : Wear eye protection/ face protection.
Hand protection : Wear the following personal protective equipment: Standard glove type. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough. Skin protection : Personal protective equipment comprising: suitable protective gloves, safety goggles and protective clothing Respiratory protection :When workers are facing concentrations above the exposure limit they must use appropriate certified respirators.
Exposure Limits:
 
Ingredients CAS No Form of exposure Value UK EH40 OES (table 2 )
Sulphur Dioxide 7446-09-5 TWA  5.3 mg/m3 2 ppm
    STEL 13 mg/m3 5 ppm
 Ethane-1-2-Diol  107-21-1 TWA 52 mg/m3  20 ppm
    STEL 104mg/m3 40 ppm
Oropan-2-ol 67-63-0 TWA  999 mg/m3 400 ppm
    STEL 1,250 mg/m3  500 ppm
Hygiene measures Handle in accordance with good industrial hygiene and safety practice. Remove and wash contaminated clothing before re-use. Wash face, hands and any exposed skin thoroughly after handling. Provide suitable facilities for quick drenching or flushing of the eyes and body in case of contact or splash hazard.

                                       

            Gloves                       Suit                          

  

Form         Liquid
Colour Colourless to slightly Yellow
Odour Acrid, slight odour of Sulphur dioxide
Boiling point and boiling range  No Data Available
Flash Point >100°C
Freezing Point No Data Available
pH 6
Evaporation rate No data available
Flammability (solid, gas) No data available
Upper explosion limit No data available
Lower explosion limit No data available
Explosive properties No data available
Vapor pressure No data available
Relative vapor density No data available
Relative density 1.05-1.11 g/cm3 (25C)
Water solubility Soluble
Solubility in other solvents No data available
Partition coefficient: octanol No data available
Autoignition temperature No data available
Thermal decomposition No data available
Viscosity, kinematic No data available
Explosive properties No data available
Oxidizing properties No data available
Molecular weight No data available
VOC No data available
Recativity                                             None
Stability Stable under normal  conditions.
Possibility of hazardous reactions No dangerous reaction known under conditions of normal use.
Incompatible materials Avoid to contact with strong acids
Avoid to contact with oxidizing agents.
Store away from aldehydes.
Hazardous Decomposition

Decomposition products may include the following materials:
Sulphurous oxides (SOx)
Nitrous oxides (NOx)
Ammonia
Amines

Condition to Avoid None Known
Polymerization Will not occur.
Route of Exposure Inhalation, Eye contact, Skin contact
Eyes                                    

Causes serious eye damage.

Skin Causes severe skin burns.
Ingestion  Causes digestive tract burns
Inhalation Inhalation of vapours leads to irritation of respiratory tract and mucous membranes, headache, nausea, dizziness, vomiting. Sensitisation possible through inhalation
Chronic Exposure Health injuries are not known or expected under normal use.
Acute oral toxicity LD50 200-2,000mg/kg
Acute inhalation toxicity No data available
Acute dermal toxicity No data available
Classification The classification was made by the conventional (calculation) method of Dangerous Preparations Directive(1999/45/EC)


Environmental Effects No data available
Toxicity to fish No data available
Toxicity to daphnia  and others No data available
Toxicity to algae                       No data available
Biodegradability  > 60% (28 d)
Persistence and degradability No data available
Bioaccumulative potential No data available
Mobility in soil No data available

 

Remarks Please consider the relevant national or regional provisions. Waste shall be separated into the categories that can be handled separately by the local or national waste management facilities.
Waste Disposal The product should not be allowed to enter drains, water courses or the soil. Where possible recycling is preferred to disposal or incineration. If recycling is not practicable, dispose of in compliance with local regulations. Dispose of wastes in an approved waste disposal facility

 Land transport (DOT)

UN        Number                                          1760
Proper shipping name Corrosive liquid, n.o.s.
Class 8
Packing Group II
Remarks Shipment Permitted
Hazardous Indoucer(S) Quaternary ammonium chloride

ADR/ ADNR

UN        Number                                          1760
Proper shipping name Corrosive liquid, n.o.s.
Class 8
Packing Group II
Remarks Shipment Permitted
Hazardous Indoucer(S) Quaternary ammonium chloride

IATA

UN        Number                                          1760
Proper shipping name Corrosive liquid, n.o.s.
Class 8
Packing Group II
Remarks Shipment Permitted
Hazardous Indoucer(S) Quaternary ammonium chloride

  International Maritime Dangerous Goods Code (IMDG) :

UN        Number                                          1760
Proper shipping name Corrosive liquid, n.o.s.
Class 8
Packing Group II
Remarks Shipment Permitted
Hazardous Indoucer(S) Quaternary ammonium chloride
Labelling in accordance with EC-Directives: Hazardous symbols
C Corrosive
R phrases 22 Harmful is swallowed
31 Contact with acids liberates toxic gas
34 Causes burns
S pharses 26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
27 Take off immediately all contaminated clothing.
36/37/39 Wear suitable protective clothing, gloves and eye/face protection
45 In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).
60 This material and its container must be disposed of as hazardous waste.
HMIS                               
Health Hazard : 2
Fire Hazard : 2
Reactivity : 0
Personal Protection : H
Fire :                              
Health Hazard : 2
Fire Hazard : 2
Reactivity : 0
Specific Hazard : 0
Other Information  

The information above is believed to be accurate and represents the  best information   currently    available  to us.  However,   we   make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and  we assume  no liability resulting from its use. Users should make  their  own  investigations  to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International  has been advised of the possibility of such damages.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Pipe Line and Tank Hydro Testing Corrosion Inhibitor RXSOL 4000 is Hydro-testing corrosion protection for Pipeline, Tank.  RXSOL 4000 Chemical for conditioning of hydro test water i.e. blend of corrosion inhibitor, one Oxygen scavenger, one scale inhibitor & one biocide manufacturer exporter and supplier Mumbai, Surat, Gandhidham, Chennai, Ennore, Visakhapatnam, Kolkata, Haldia, Paradip, Fujairah, Sharjah, Ajman, Abudhabi, Dubai UAE Middle East, Muscat Oman Sohar, Canada

DESCRIPTION :

RXSOL 4000 is a multicomponent, multifunctional formulation which prevents corrosion, microbiological growth in single product treatment programme.

PERFORMANCE:

CORROSION
: Effectively prevents corrosion due to Carbon Dioxide, inorganic salts, dissolved oxygen & Hydrogen sulphide contamination from sour fluid or bacterial action. The inhibitor acts as a cathodic polarizer.

MICROBIOLOGICAL GROWTH: Effectively prevents the metabolic function necessary for reproduction of the bacteria cell. Successfully prevents anaerobic/aerobic and sulphate reducing bacteria.

APPLICATION :

Inhibitor, corrosion, multicomponent, multifunctional: For prevention of corrosion and microbiological growth in water flood systems during hydrostatic testing and other applications

DOSE :

RXSOL 4000 can be fed directly or through chemical doses pump. Doses may vary with the quality of water to be treated and the residence time of the water in the system.

DOSING RATE OF RXSOL 4000

Minimum 50 LPH

Maximum 125 LPH

Actual dosing rate shall be proportionate to pumping rate.

Flow Rate Of The Product

Minimum M3/ HR : 150.0

Maximum M3/ HR : 350.0

Location for dosing of RXSOL 4000 corrosion inhibitor chemical

# Corrosion inhibitor shall be dosed in the displacement water piping at the suction of main pump/ booster pump

For Storage tank it can dose 0.50 to 0.15 Ltr per 100 Ltr Water.

CHEMICAL SPECIFICATION :

Form                                         Liquid
Colour Colourless to slightly Yellow
Odour Sharp
Flash Point  > 100C
Density 1.05-1.11 g/cm3 (25C)
pH 3 - 7

Benefit  / Advantage :

  • RXSOL 4000 is a liquid multifunctional chemical designed to completely treat hydrostatic test fluid, saltwater packer fluid, saltwater drilling fluid, during Hydro-testing and oil field water injection programme.
     
  • RXSOL 4000 contains an effective filming corrosion inhibitor, oxygen scavenger and biocide, altogether in a single formulation convenient to dose with single chemical injection pump or skid.
     
  • RXSOL 4000 is economical to use as handling is limited to one chemical.

TECHNICAL DATA SHEET

CORROSION PROBLEMS DURINGHYDROTESTING OF PIPELINES

The major factor which contributes to the corrosion in hydro-static test water is the dissolved oxygen and dissolved solids do not have much impact on the corrosion rate except the chloride content. The presumptions like not using the corrosion inhibitor if the water is not with high mineral content could beM disastrous as in fact any corrosion process, even a very mild one, will be accompanied by the set up of galvanic cells and formation of corrosion products deposits. Such environment makes the conditions ideal for the corrosion process to continue at accelerated rate once the process fluid will be run through the line.

Effect of Dissolved Oxygen:

Dissolved oxygen plays a key role in corrosion or iron in natural waters, but its effects can be conflicting and partially dependent on other environmental factors. In near neutral pH waters at ambient temperature, dissolved oxygen provides the reduction reaction which sustains the corrosion of iron. However, oxygen also plays a role in formation of semi-protective iron oxide films on the metal, and the more protective films are formed at higher oxygen concentrations. Once these films are formed, however, oxygen provides the main driving force for initiation of pitting (leading to tuberculation) or other forms of localized corrosion. The first part of this discussion is for conditions in the absence of calcium carbonate or other external inhibiting species.
 

At sufficiently high pH values, iron oxide or hydroxide layers can be formed. The first of these is probably ferrous hydroxide which can be formed by an overall reaction such as

Fe + H2O + 1/2 O2 = Fe (OH)2

This solid is often found next to the metal surface and can act as a diffusion barrier to oxygen. Further oxidation of this product yields hydrous ferric oxide which comprises most of ordinary rust. An intermediate oxidation stage, Fe3O4. nH2O often forms as a layer between the ferric and ferrous compounds. In the absence of dissolved oxygen, the corrosion rates for both pure iron and steel becomes negligible in near neutral pH water at room temperature.
 

Corrosion rates may be high when the metal is first exposed to air-saturated water, but the iron oxide films formed over a period of a few days act as a barrier to diffusion of oxygen to the surface and a steady state corrosion rate is obtained. This steady state rate is proportional to oxygen concentration, since the oxygen diffusion rate is proportional to its concentration.
 

An oxygen concentration of about 6 mg/l corresponds to air-saturated water. At still higher oxygen concentrations, the uniform corrosion rate of mild steel may decrease abruptly. This effect is apparently due to passivation of the iron which involves either the oxidation of the normal ferrous hydroxide layerto one which has better protective properties or the formation of a thin chemisorbed oxygen layer on the metal surface. More oxygen is required in waters containing chloride ions and passivation of mild steel cannot occur if the chloride concentration is high enough. The breakdown of passivity in the presence of moderate amounts of chlorides (more than about 20 ppm, see below) is often accompanied by severe pitting or crevice corrosion. The effect of solution flow rate on mass transport of oxygen to the corroding surface can also give rise to diverse effects. At moderate oxygen concentrations and flow rates, increasing the flow rates increases the corrosion rate due to the increase in amount of oxygen transported to the surface. At higher flow rates, the surface oxygen concentration can become high enough to cause passivation, provided the chloride content is not too high. Still higher flow rates, over 4.0 M/sec, can greatly accelerate corrosion by erosion of the protective films, combined with fast transport of oxygen to the surface by turbulent flow. At the other extreme, stagnant conditions are usually
most conducive to pitting and other forms of localized corrosion. The threshold for chloride effects on passivity is ill defined. As little as 20 ppm. Chloride may cause breakdown and pitting but the threshold may be higher depending on solution composition.

Effect of Dissolved Salts:


Dissolved salts (for example, ions such as Na+, Cl- , SO42-, Ca2+ , Mg2+, HCO3, CO32-can have a number of effects, some of which depend only on the general effect of ions, whileothers depend on the individual chemical species. Examples of the first class of effects are given below.

Increasing salt concentration increases solution conductivity which can have several effects.

Increasing salt concentration generally decreases the equilibrium concentration of dissolved oxygen and CO2

Contrary to early predilections, solution conductivity itself has little effect on most modes of uniform or localized corrosion. This is because the local anodes and cathodes are so close together that the resistance offered by the solution is much less than equivalent electrochemical reaction rate resistance. Solution  conductivity can, however, affect the range over which the effects of attack due to galvanic coupling of dissimilar metals is extended. Attack can extend for example, from about 1 cm. from the joint in soft waters to more than 10 cm. in water with significant dissolved salt content. Changes in solution conductivity can have more subtle and significant effects. It has been proposed that moderate increases in conductivity (by dissolved NaCl) from that of very soft or distilled water can lead to increased corrosion rates due to formation of a less protective Fe (OH)2 film. The film is less protective since it is formed further away from the surface than in less conductive waters. This in turn is due to coupling of local anodic (source of Fe 2+) and cathodic (source of OH-) areas at greater distances in the more conductive solution. The initial increase in corrosion rate might also have to do with some specific effects of chloride and a number of postulates on these effects have been offered. Specific effects of chloride are discussed below.

There is little direct evidence for either the Fe (OH)2 film or chloride effect arguments. It has recently been proposed that an increase in solution con-ductivity may have the effect of actually promoting a more protective coating on iron in the presence of Calcium Carbonate film forming precursors. Correlation between the electrical impedance and protectiveness of scales and a quantity related to the conductivity of the solution was found. Conductive salts facilitate protective film formation, provided that sufficient temporary hardness exists.
 

The other overall effect of dissolved salts that of decreasing the solubility of dissolved gases. Since the dissolved oxygen content is the main controlling factor under the conditions, "salting out" of oxygen causes a decrease in corrosion rate.

 

Technical Notes


This effect only becomes pronounced at higher salt concentrations and is most likely unimportant in natural fresh waters. Chloride is the most deleterious individual ionic species normally occurring in natural waters. Much of this appears to be due to the ability of chloride to promote pitting by penetration or local destruction of otherwise protective iron oxide films. It is quite difficult for a uniform, true passive iron oxide film to be formed in the presence of chloride ions. It is difficult, however, to quantify the relation of corrosivity to chloride concentration in natural waters. The threshold concentration of chloride above which pitting of iron is possible, is said to be About 10 ppm. The role of sulfate is more nebulous, especially since sulfate does not appear to have the film piercing properties that chloride displays.
The corrosivity of air-saturated domestic waters depends on the following factors
.
The proportion of corrosive agents (chloride and sulfate ions) to inhibitive agents (bicarbonate, carbonate, hydroxide, and calcium ions).

The concentration and degree of effectiveness of the corrosive and inhibitive species.

The velocity of flow which affects the rates of diffusion of both types of species to the surface.

The relative effectiveness of the species involved is not definitive, but may be influenced by one or more of the others. The interdependence of the relevant factors is also emphasized by the observation that "intermediate proportions" of corrosive to inhibitive species, which result in incomplete protection (to uniform corrosion) at a particular solution flow rate, are conducive to pitting and/or tuberculation.

Effect of Micro – Organisms:


All water used for Hydro-testing generally contains iron bacteria and sulphate reducing bacteria. The iron bacteria attack to the pipe wall mostly at 6 o’clock location and produces tubercle of iron oxide by metabolic action. Below the tubercles, sulphate reducing bacteria grows and generates H2S from sulphate of water. The H2S goes on reacting with iron forming Fe2S. This is combined with auto catalytic formation of HCI under tubercle and lead to deep pitting and perforation of the pipe wall. The mechanism is more pronounced under stagnant condition and is relevant of Hydrostatic testing.

Our stock points and branches