RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Power Plant / Heavy Industries

Fuel Additive BIOCIDE Liquid

Excellent control of fouling by shellfish, micro-organisms and fungal growth in FUEL systems. Its use will discourage the setting of the free-swimming larval form of the molluc, which discourage corrosion of metal in the FUEL system.
Part number
RXSOL-70-7008-210
Brand
RXSOL
Fuel Additive BIOCIDE Liquid

Overview

RXSOL ANTIFOULANT LIQUID has been developed for the control of fouling by shellfish, micro-organisms and fungal growth in FUEL systems. Its use will discourage the setting of the free-swimming larval form of the molluc. Because of its molecular film-forming properties RX ANTIFOULANT LIQUID will discourage corrosion of metal in the FUEL system.

This products is highly beneficial to prevent growth of ORGANISM like bacteria / fungi in STORAGE TANK of PETROLEUM PRODUCTS.

Now a days ULSD fuel is covering maximum fuel demand for Automobile industries, On other hand Ultra Low Sulfur Diesel (ULSD) fuel has more problems with microbial contamination than previous higher sulfur fuels. Since ULSD can no longer carry water dissolved in solution, more water is shedding to the bottom of fuel tanks, creating a life-support system and breeding ground for microbes. Parrafin content has increased as sulfur and aromatics decrease, providing a major food source to microbes. Additionally, sulfur is a natural poison to bacteria and fungus and its reduction has further exacerbated microbial contamination problems in ULSD.

Applications

  • Highly effective in both diesel fuel and water
  • Usefull to maintain long-term diesel fuel maintenance
  • Kills microbes (bacteria and fungus) that grow in dispersed and free water associated with diesel fuels
  • Prevents fuel-filter plugging – helps prevent fuel system failures
  • Protects fuel system components against organic acids created by microbial growth – prevents fuel tank corrosion
  • Improves fuel performance
  • Reduces engine maintenance costs
  • Effective in all diesel fuels, including Ultra Low Sulfur Diesel (ULSD), biodiesel and biodiesel blends
  • Does not contain alcohol of any kind
  • Safe for use in all diesel engines
  • Will not void engine manufacturer's warranty when used as directed

Dosage and directions

Problem and identification due to growth of Microbial.

The first indication of microbial contamination is mucous-like accumulations on fuel-filters and increased requirements for fuel-filter replacement.

Solution :::

RXSOL-70-7008 biocide effectively kill microbes to avoid microbial contamination in tank and filter. 

Treatment with RXSOL-70-7008 Diesel Fuel Biocide to kill the microbes and Clear-Diesel Fuel & Tank Cleaner to remove the residual water and contaminants.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name : RXSOL-70-7008-210
Product Type : Fuel Additive BIOCIDE Liquid-III

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kandla, Kolkata, Chennai, Vizag, Fujairah, Muscat

Phone : +91 22 65113333 / 5555 / 9999 / 27611360
Fax : +91 22 2781 1318 :::AOH :0091 9821214367
Email : rxsolchemicals@gmail.com

 

 - ALIPHATIC HYDROCARBON  , Fatty Amine  ,Alcohol Ethoxylate

Environmental Hazards

:

None

Human Health  Hazards

:

Moderates

Effect & Symptoms  : -

Ingestion

:

Harmful, if ingested. Remove to fresh air . Obtain medical attention ( without medical advice do not induce vomiting ).

Inhalation

:

Remove to fresh air . Treat symptomatically . Obtain medical attention.

Skin Contact

:

Non Irritation . Remove contaminated cloth , wash off with soap and plenty of water .

Eye Contact

:

Cause Irritation . Move eyeball with plenty of clean water for atleast 15 minutes . Obtain medical attention.

A. Suitable   Foam

:

Dry Co2

B. Not suitable

:

Not applicable

C. Special

:

Not applicable

Protection of fire Fighter

:

Not applicable ( wear pressurised self contained breathing apparatus )

BIOACCUMULATION POTENTIAL

:

No data available

DEGRADATION

:

Non- Hazardous

Skin Irritation

:

No.

Sensitization

:

Not Sensitizing

Chronic Toxicity

:

Not Identified

Carcinogencity

:

No.

Respiratory System Protection

:

Approved respirator must be worn when spraying

Eye Protection

:

Chemical splash goggles

Hand Protection

:

PVC gloves

Condition to Avoid

:

Heat, Flame & Other Sources of Ignition

Materials  to Avoid

:

Do not subject to Acidic/Highly Alkaline/Oxidizing Agents.

Hazardous Decomposition Products

:

Do not occur (Bio-Degradable) 

Odour

Characteristic

Appearance

Liquid, dark yellowish-red

pH

not applicable

Boiling point

175 °C to 220 °C at 760 mm /Hg

Melting point not known
Density 0,85 g/cm3 at 20 deg C
Auto-ignition point 220 deg C
   
 
 

- This article is considered stable under normal conditions
- Keep away from naked flames, incandescent or hot surfaces
- See Section 5

Inhalation

Inhalation of solvent vapours may give rise to nausea, headaches and dizziness

Contact with skin

Prolonged skin contact will result in defatting of the skin, leading to irritation, and in some
cases, dermatitis

Contact with eyes

May cause redness and irritation

Ingestion Aspiration hazard. The ingestion of significant quantities may cause damage to lungs
Ecotoxicity This product does not contain ingredients which are classified in the EU as dangerous for the environment. LC50 (fish) 10-100 mg/l (96 hr)

Persistence and degradability

OECD-test. 28 days

Bioaccumulation Potential

Hydrocarbon solvents have the potential to bioaccumilate.

Waste treatment methods

Do not discharge into drains or the environment, dispose to an authorised waste collection point. Disposal should be in accordance with local, state or national legislation

Classification EU Waste class: 07.01. This material and/or its container must be disposed of as hazardous waste

Special precautions for user
- Not classified as hazardous for transport

Classification and labelling Counsil Directive 1999/45/EEC Classification, packing and labelling of dangerous preparations.. This Safety Data Sheet is provided in compliance with TheDangerous Substances Directive (67/548/EEC) Safety, health and environmentalregulations/legislation specific for the substance or mixture. This Safety Data Sheet has been prepared in accordance with article 31 and annex II in REACH and Directive 453/2010/EU.

Text of R and S phrase codes used in this safety data sheet:- R65: Harmful: may cause lung damage if swallowed; R66: Repeated exposure may cause skin dryness or cracking. The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other application(s) without seeking advice from manufacturer

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Fuel Additive BIOCIDE Liquid manufacturer, supplier, exporter in Mumbai, Kandla, Howrah, Visakhapatnam, Chennai, India. Ready stock of Fuel Additive BIOCIDE chemical in Fujairah, Sharjah, Muscat Barka, Oman, Kenya, Canada.

Our stock points and branches