Corrosion Inhibitor

Corrosion Inhibitor for Central Air Chiller

Corrosion inhibitor for absorption chiller for industrial central air conditioning
Part number
RXSOL-44-9001-300
Brand
RXSOL
RXSOL

Overview

Corrosion Inhibitor for Central Air Chiller used as corrosion inhibitor in LiBr (Lithium bromide) absorption chiller for industrial central air conditioning. It is manufactured and shipped as either a colorless, transparent fluid or a white crystal powder. In either state it not classified as a hazardous material.

Applications

It is an absorption chiller for industrial central air conditioning

Characteristics and notes

We are keeping ready stock of Corrosion Inhibitor for Central Air Chiller. We are one of popular supplier of Superior Quality Of Corrosion Inhibitor for Central Air Chiller.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name            Corrosion Inhibitor for Central Air Chiller
Part Number RXSOL-44-9001-300
Chemical Family Inorganic Bromide
Type of product and use Inorganic solution used as desiccate medium in air conditioning and cooling systems.

Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.

VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kandla, Chennai, Visakhapatnam, Kolkata, Fujairah, Muscat OMAN, Kenya, Canada

Phone +91 22 27815540 / 41 / 42
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
Website www.rxmarine.com
Name     of        Substance                          Cas Number EC Number Wight %
Lithium Bromide 7550-35-8 231-439-8  55
Lithium Molybdate 13568-40-6 236-977-7 1-2
Proprietary Blend - - 40-50

 

Signal Word  Warning
Adverse human health effects Risk of serious damage to eyes.


Eye Contact:

Holding the eyelids apart flush eyes promptly with copious flowing water for at least 20 minutes. Get medical attention immediately.

Skin Contact : Remove contaminated clothing. Wash skin  thoroughly with mild soap and plenty of water for at least 15 minutes. Wash clothing before reuse. Get medical attention if irritation persists.
Inhalation: In case of inhalation or breathing fumes released from heated material, remove person to fresh air. Keep him quiet and warm. Apply artificial respiration if necessary and get medical attention immediately.
Ingestion: If swallowed, wash mouth thoroughly with plenty of water and give water or milk to drink. Get medical attention immediately.
NEVER GIVE AN UNCONSCIOUS PERSON ANYTHING TO DRINK.

Flash  Point                         None.
Auto-ignition temperature   Not Available.
Flammable/Explosionlimits  Not Available
Etinguishing media Material is not combustible. Use extinguishing media appropriate to surrounding fire conditions.
Fire fighting procedure Cool containers with water spray. In closed stores, provide fire-fighters with self-contained breathing apparatus in positive pressure mode.
Usual fire and explosion hazards None known.
 

Personal precautions  

Wear respirator, chemical safety goggles, rubber gloves and boots.

After spillage / leakage Absorb on sand or vermiculite and place in closed container for disposal. Ventilate area and wash spill site after material pick-up is complete. Avoid access to streams, lakes or ponds.
Disposal Considerations Avoid access to streams, lakes or ponds.Observe all federal, state and local environmental regulations when disposing of this material.

Handling

Avoid bodily contact. Keep containers tightly closed.

Storage Store in a cool, well-ventilated area away from incompatible materials.
Ventilation requirements                     Provide adequate ventilation. Use local exhaust as necessary, especially under misting conditions.
Personal protection equipment   
Respiratory protection : Approved respirator.
Gloves : Rubber gloves.
Eye Protection: Chemical safety goggles.
Others : Body covering clothes and boots.
Industrial hygiene : Safety shower and eye bath should be provided.Do not eat, drink or smoke until after work showering and changing clothes.
Appearance:                                         Clear, colourless to yellow liquid, odourless.
Melting Point / range : 10oC (58%)
Boiling Point / range : 145 - 147oC (55%)
Vapour Pressure : 2.1 mm Hg at 20oC (55%)
Relative vapour density (air=1) : Not available.
Evaporation rate (either=1) : Not available.
Solubility in Water : 70 gr/100ml at 101oC
Solubility in other Solvent: Miscible with Methanol, Ethanol (absolute),n-Propanol.
Thermal decomposition : Not available.
Stability                             Stable under normal conditions.
Materials to avoid : Strong acids. 
Conditions to avoid : None known.
Hazardous decomposition-products : Hydrobromic Acid gas above 200oC
Hazardous Polymerization: Will not occur.
Effect   of   overexposure                    
Ocular :                                        Severe irritant.              
Dermal : Mild irritant to intact skin.
Inhalation : May irritate the upper respiratory tract.
Ingestion : May cause vomiting, nausea, diarrhea and ataxia. Slurred speech, blurred vision, dizziness, sensory loss, convulsions and stupor may occur in cases of large intake.
Chronic toxicity : Repeated skin contact may cause dermatitis.Repeated oral intake of bromides may affect the central nervous system. Warning symptoms include mental dullness, slurred speech,weakened memory, apathy, anorexia, constipation, drowsiness and loss of sensitivity to touch and pain.
Carcinogenicity : Not known to be a carcinogen.
Mutagenicity : Not mutagenic by the Armes Test.
Aquatictoxicity              : 48 Hour-EC50
Daphnia magna : 45 mg/l                        
Waste treatment Method Avoid access to streams, leaks or ponds. Observe all federal, state and local environmental regulations when disposing of this material.

UN No. : Not regulated.
IMO-IMDG CODE : Not regulated.
ICAO / IATA : Not regulated.
RID / ADR : Not regulated.
US DOT : Not regulated.
Classification : Irritant symbol required and dangerous to the environment.
 R Phrase(s) : R 41 : Risk of serious damage to eyes.
R 52 : Harmful to aquatic organisms. 
S Phrases :                    S 26 : In case of contact with eyes, rinse mmediately with plenty of water and seek edical advice.
S 39 : Wear eye / face protection.
S 61 : Avoid release to the environment. Refer o special instructions / Safety Data Sheets.
Revision Information: None
Other Information

The information above is believed to be accurate and represents the  best information   currently    available  to us.  However,   we   make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and  weassume  no liability resulting from its use. Users should make  their  own  investigations  to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if RX Marine International  has been advised of the possibility of such damages.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Corrosion Inhibitor for Central Air Chiller Manufacturer, Supplier and a leading Exporter of Corrosion Inhibitor for Central Air Chiller. We are keeping ready stock of Corrosion Inhibitor for Central Air Chiller solution in Kandla, Mumbai, Chennai, Visakhapatnam, Kolkata, Fujairah, Dubai, Sharjah, Muscat Barka Oman, Kenya Nairobi.